Document Type
Article
Abstract
The development of a facility for irradiation of murice and primate tissue presents several challenges. First, extremely low fluences (10⁶-10¹¹ ions cm⁻²) are required to deliver doses of 1 mGy - 50 Gy using MeV proton. Second,the tissues, particularly from non-human primate, may be infectious to humans. Third, protection of irradiated tissue samples from contamination by mold and bacteria is critical. Here we present an ultra-low flux irradiation facility and associated fluence control for biological cell and tissue irradiation under sterile biosafety level 2 (BSL-2) conditions suitable for use with low energy (1-3.4 MeV) protons. The operation is demonstrated using murine astocytes.
DOI
https://doi.org/10.1016/j.nimb.2019.03.002
Publication Date
2019
Recommended Citation
Diaz, Jay D.; Deoli, Naresh T.; Rogers, Deborah; de Vera, Armin; Smith, Karen M.; Schmeider-Broussard, Robin; and Whitlow, Harry J., "Development of a biosafety level-2 facility for irradiation of biological cells using MeV ions" (2019). Louisiana Accelerator Center. 1.
https://scholarshub.louisiana.edu/lac/1